- Source: Camera Link
Camera Link is a serial communication protocol standard designed for camera interface applications based on the National Semiconductor interface Channel-link. It was designed for the purpose of standardizing scientific and industrial video products including cameras, cables and frame grabbers. The standard is maintained and administered by the Automated Imaging Association or AIA, the global machine vision industry's trade group.
Transmission protocol
Camera Link uses one to three Channel-link transceiver chips with four links at 7 serial bits each.
At a minimum, Camera Link uses 28 bits to represent up to 24 bits of pixel data and 3 bits for video sync signals, leaving one spare bit.
The video sync bits are Data Valid, Frame Valid, and Line Valid. The data are serialized 7:1, and the four data streams and a dedicated clock are driven over five LVDS pairs. The receiver accepts the four LVDS data streams and LVDS clock, and
then drives the 28 bits and a clock to the board.
The camera link standard calls for these 28 bits to be transmitted over 4 serialized
differential pairs with a serialization factor of 7. The parallel data clock is transmitted
with the data. Typically a 7× clock must be generated by a PLL or SERDES block in
order to transmit or receive the serialized video. To deserialize the data,
a shift register and counter may be employed. The shift register catches each of the serialized bits, one at a time,
then registers the data out into the parallel clock domain - once
the data counter has reached its terminal value.
Variants
Camera Link comes in several variants which differ in the amount of data that can be transferred. Some of them require two cables for transmission.
= Base configuration
=The "Base" Camera Link configuration carries signals over a single connector/cable. The cable used is a MDR ("Mini D Ribbon") 26-pin Male Plug Connector, optimized by 3M for the LVDS signal. In addition to the 5 LVDS pairs transmitting the serialized video data (24 bits of data and 4 framing/enable bits), the connector also carries 4 LVDS discrete control signals and 2 LVDS asynchronous serial communication channels for communicating with the camera. At the maximum chipset operating frequency (85 MHz), the base configuration yields a video data throughput of 2.04 Gbit/s (255 MB/s).
= Medium/Full configuration
=The Camera Link specification includes higher-bandwidth configurations that provide additional video data paths over a second connector/cable. The "Medium" configuration doubles the video bandwidth, adding 24 bits of data and the same 4 framing/enable bits present in the "Base" configuration. This yields a 48-bit wide video data path capable of throughput up to 4.08 Gbit/s (510 MB/s). The "Full" configuration adds another 16-bits to the data path, resulting in a 64-bit wide video path that can carry 5.44Gbit/s (680 MB/s).
= Deca configuration
=Some camera and data acquisition hardware manufacturers have extended the bandwidth of the interface beyond the limits imposed by the Camera Link interface specification. These formats extend the width of the "Full" configuration by utilizing 8 unused bits and reassigning the 8 redundant framing/enable bits to produce a data path width of up to 80 bits over two connectors/cables, which further increases the video bandwidth. A consensus has emerged in the industry about the 80-bit variant, and compatible cameras and frame grabbers are marketed with the term "Camera Link Deca". However, some manufacturers use the term "Extended Full" to refer to Deca configuration, and still others retain use of the term Camera Link Full while referring to Full Deca. The 80-bit video path can carry 6.8 Gbit/s (850 MB/s).
Signal timing
The image below shows the relative signal timing of the clock and one data line of one of the Channel Link transceivers used for Camera Link transmissions. Data words start in the middle of the high phase of the clock, and the most significant bit is transmitted first.
Bit assignments
The bits of pixel values are not assigned to serial transmitters in order, but are permutated in a complicated way, as shown in the following figure. The figure labels the Camera Link data bits consecutively and includes 8 additional bits not part of the Camera Link Full specification. (The Camera Link standard divides the data bits into eight 8-bit ports denoted by letter-number combinations, but uses the same letter-number combinations for color channels that do not always correspond one-to-one, making this notation ambiguous.)
The upper half of this figure is only relevant for the Medium and Full configurations which require two physical interfaces and two cables. The two rectangles in the middle represent the cables, with the connector pins of each signal printed at either side.
To the left of the transceivers, the list of pixel data bits transmitted over that Channel Link is printed, from LSB to MSB. The characters L, F and D refer to the Line Sync, Frame Sync and Data Valid bits, respectively. The underscore represents an unused spare bit. It remains to be said how pixel data bits are assigned to the bits 0 to 71 used in the figure. For grey-scale pixels, this is a trivial one-to-one mapping; for colour pixels with a multiple of 8 bits per colour, the colours are simply concatenated in the order red, green and blue (from LSB to MSB). For 12-bit RGB data, the lower 8 bits of each colour are assigned to data bits 0–7,16-23,32-39; the higher 4 bits of each colour to bits 8–11,12-15,40-43.
Cables and connectors
The standard prescribes 26-pin Miniature Delta Ribbon connectors (MDR-26) for use with Camera Link; the shrunk variant SDR-26 is allowed since standard version 1.2. The connector pin assignments are shown in the large figure in the previous section. The connector pinout is the following:
Matching differential pairs are deliberately located at opposite sides of the connector, and at different connector sides at the different ends of the cable. This prevents skew due to the connector being mounted perpendicularly on a PCB.
Camera Link cables are shielded twisted pair cables. The standard specifies that differential pairs must be individually shielded, and the cable as a whole must have two shields. Some companies save costs by not shielding the two serial interface signal pairs, which carry slower signals than the camera data; these cables have one camera end and one grabber end and may not be reversed, and cannot be used as a second cable in a Medium or Full configuration.
Interface Standard Specifications
The Camera Link standard is maintained by the AIA. The introduction of the Camera Link Interface Standard (1.0) was released in October 2000. Revision 1.1 was adopted in January 2004, with expanded software function support. The standard committee adopted version 1.2 in January 2007, introducing mini SDR ("Shrunk D Ribbon") connectors (SDR-26) and power over Camera Link (POCL). Annex D of revision 1.2 adds mechanical and electrical descriptions to the standard, especially cable performance. Annex E of revision 1.2 lists requirements of POCL equipment. Camera Link 2.0 was released in November 2011.
See also
Channel Link
Automated Imaging Association
GigE vision
List of device bandwidths
Low-voltage differential signaling (LVDS)
CoaXPress
Camera Serial Interface
Notes
External links
Automated Imaging Association, the body responsible for the Camera Link standard
Camera Link standard V1.0, October 2000
Camera Link HS, Camera Link High Speed Standard w/ support for fiber cabling and up to 16,000 MB/s
Kata Kunci Pencarian:
- Kamera
- Kamera aksi
- Far Ultraviolet Camera/Spectrograph
- Game Boy Camera
- D-Link
- TP-Link
- PlayStation 4
- YouTube
- Caramel (film)
- NC-212
- Camera Link
- TP-Link
- Camera
- Camera Serial Interface
- Mirrorless camera
- History of the camera
- Traffic enforcement camera
- Digital camera
- Insta360
- Camera obscura
No More Posts Available.
No more pages to load.